MAD100
FEATURES APPLICATIONS
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 3.00 X 1.16 INCH
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT


MAD40
FEATURES APPLICATIONS
• LOW STANDBY POWER CONSUMPTION UNDER 0.11 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• BUILT-IN CLASS B EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY)
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• SAFETY MEETS ANSI/AAMI ES60601-1, EN60601-1 AND IEC60601-1 3rd EDITION
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT


MAD65
FEATURES APPLICATIONS
• LOW STANDBY POWER CONSUMPTION UNDER 0.11 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• BUILT-IN CLASS B EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY)
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• SAFETY MEETS ANSI/AAMI ES60601-1, EN60601-1 AND IEC60601-1 3rd EDITION
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT


MAF150
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 4.00 X 1.16 INCH
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 100μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT


MDD100
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 3.00 X 1.16 INCH
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT


MDD40
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.11 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• BUILT-IN CLASS B EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY)
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• SAFETY MEETS ANSI/AAMI ES60601-1, EN60601-1 AND IEC60601-1 3rd EDITION
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT


MDD65
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.11 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• BUILT-IN CLASS B EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY)
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• SAFETY MEETS ANSI/AAMI ES60601-1, EN60601-1 AND IEC60601-1 3rd EDITION
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT


MDF150
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 4.00 X 1.16 INCH
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 100μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT


MED100
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 3.00 X 1.16 INCH
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT


MED40
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.11 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• BUILT-IN CLASS B EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY)
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• SAFETY MEETS ANSI/AAMI ES60601-1, EN60601-1 AND IEC60601-1 3rd EDITION
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT


MED65
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.11 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• BUILT-IN CLASS B EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY)
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• SAFETY MEETS ANSI/AAMI ES60601-1, EN60601-1 AND IEC60601-1 3rd EDITION
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT


MEF150
FEATURES
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 4.00 X 1.16 INCH
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 100μA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT


MOP03
FEATURES
• REINFORCED INSULATION FOR 300VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE : 6.6mm/2MOOP
• 3000VAC INPUT TO OUTPUT 2MOOP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1
SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MOP03W
FEATURES
• REINFORCED INSULATION FOR 300VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE : 6.6mm/2MOOP
• 3000VAC INPUT TO OUTPUT 2MOOP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1
SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MOP06
FEATURES
• REINFORCED INSULATION FOR 300VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :6.6mm/2MOOP
• 3000VAC INPUT TO OUTPUT 2MOOP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MOP06W
FEATURES
• REINFORCED INSULATION FOR 300VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :6.6mm/2MOOP
• 3000VAC INPUT TO OUTPUT 2MOOP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MOP10
FEATURES
• REINFORCED INSULATION FOR 300VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :6.6mm/2MOOP
• 3000VAC INPUT TO OUTPUT 2MOOP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MOP10W
FEATURES
• REINFORCED INSULATION FOR 300VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :6.6mm/2MOOP
• 3000VAC INPUT TO OUTPUT 2MOOP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MPP03
FEATURES
• REINFORCED INSULATION FOR 250VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :8.0mm/2MOPP
• 5000VAC INPUT TO OUTPUT 2MOPP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1
SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MPP03W
FEATURES
• REINFORCED INSULATION FOR 250VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :8.0mm/2MOPP
• 5000VAC INPUT TO OUTPUT 2MOPP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1
SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MPP06
FEATURES
• REINFORCED INSULATION FOR 250VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :8.0mm/2MOPP
• 5000VAC INPUT TO OUTPUT 2MOPP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MPP06W
FEATURES
• REINFORCED INSULATION FOR 250VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :8.0mm/2MOPP
• 5000VAC INPUT TO OUTPUT 2MOPP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MPP10
FEATURES
• REINFORCED INSULATION FOR 250VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :8.0mm/2MOPP
• 5000VAC INPUT TO OUTPUT 2MOPP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER


MPP10W
FEATURES
• REINFORCED INSULATION FOR 250VAC WORKING VOLTAGE
• CLEARANCE AND CREEPAGE DISTANCE :8.0mm/2MOPP
• 5000VAC INPUT TO OUTPUT 2MOPP ISOLATION
• BUILT-IN EMI CLASS A FILTER
• 2μA PATIENT LEAKAGE CURRENT
• ANSI/AAMI ES60601-1, EN60601-1, IEC60601-1, UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
APPLICATIONS
• MEDICAL EQUIPMENT
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
• PV POWER SYSTEM
• IGBT GATE DRIVER