What is load regulation / how is it calculated?
Make and record the following measurements at nominal line voltage at 25oC
- Output voltage with rated load connected to the output. (Vout FL)
- Output voltage with no load or the minimum specified load for the DC-DC converter. (Vout ML)
Load regulation is the difference between the two measured output voltage as a percentage of output voltage at rated load.